undefined
+
  • undefined

Custom Leak (Open Standard Leak) VTL-D Type

Open gas standard leak hole can specify pressure, leakage rate, etc. at the same time. Open standard leak hole does not have gas chamber or gas storage device. It needs external gas source and is suitable for any leak detector and leak detection system.

Key words: standard leak | MPCVD | capacitance film gauge vacuum gauge | high and low vacuum calibration device | helium leak calibration device

Classification:

Telephone:

Product Details

Open gas standard leak hole can specify pressure, leakage rate, etc. at the same time. Open standard leak hole does not have gas chamber or gas storage device. It needs external gas source and is suitable for any leak detector and leak detection system. Adopting advanced micro-channel technology, it has the advantages of fast response, small temperature drift (glass penetration is 3%/℃, channel type is 0.2/℃), small leakage rate and not easy to block, wide leakage rate test range, can be used with or without storage gas tank, firm structure, non-vulnerability and good stability.

 

List of Technical Parameters

VTL

-D

Leakage rate range

1E-3 Pa · m3/s ~ 5E-10 Pa · m3/s @ Other leakage rate ranges can also be customized as required

Leak element

Microchannel capillary, metal flat tube, laser drilling, can be customized according to customer needs

Interface Type

Customer customization

Type of gas

Specified gases such as Air, He, H2, deuterium, halogen, SF6, etc.

Application

As a standard leak hole, real simulation of working conditions; calibration of various gas detectors, including helium mass spectrometer leak detector, hydrogen leak detector, refrigerant leak detector, SF6 leak detector, etc.

Certificate

Dongbei CNAS laboratory or third party certificate

 

Features:Open gas standard leak hole, can specify pressure, leakage rate, etc. at the same time. The open standard leak hole does not have a gas chamber or gas storage device, and an external gas source is required for any leak detector and leak detection system.
The user can specify one or more of these conditions at the same time:Specified pressure, specified interface, specified leak rate or leak rate interval, specified outlet pressure: vacuum or atmosphere, external, internal, etc.